Features :
DMM | ||||
AC Current (True RMS) (auto/manual) | ||||
Range | Resolution | Accuracy |
Overload Protection | |
50Hz ~ 1kHz | 1kHz ~ 10kHz | |||
40mA | 10µA | ±(1.2% rdg + 10 dgts | ±(4.0% rdg + 10 dgts) | 250V/500mA fused |
400mA | 100µA | |||
4A | 1mA | ±(2.0% rdg + 10 dgts) | ±(4.0% rdg + 10 dgts) | 250V/20A fused |
20A | 10mA | |||
AC Voltage (True RMS) | ||||
Range | Resolution | Accuracy | ||
50Hz ~ 1kHz | 1kHz ~ 10kHz | 10kHz ~ 30 KHz | ||
400mV | 0.1mV | ±(1.0% rdg + 10 dgts) | ±(5.0% rdg + 10 dgts) | ns |
4V | 1mV | ±(0.75% rdg + 10 dgts) | ±(2.0% rdg + 10 dgts) | ±(5.0% rdg + 10 dgts) |
40V | 10mV | ±(0.75% rdg + 10 dgts) | ±(1.0% rdg + 10 dgts) | ±(5.0% rdg + 10 dgts) |
400V | 100mV | ±(0.75% rdg + 10 dgts) | ±(1.0% rdg + 10 dgts) | ±(5.0% rdg + 10 dgts) |
700V | 1V | ±(1.0% rdg + 10 dgts) | ns | ns |
DC Current (auto / manual) | ||||
Range | Resolution | Accuracy | Overload Protection | |
40mA | 10µA | ±(1.2% rdg + 10 dgts) | 250V/500mA fused | |
400mA | 100µA | |||
4A | 1mA | ±(1.5% rdg + 10 dgts) | 250V/20A fused | |
20A | 10mA | |||
DC Voltage (auto / manual) | ||||
Range | Resolution | Accuracy | Overload Protection | |
400Ω | 0.1Ω | ±(0.5% + 10 digits) | 250V DC or AC peak within 10 seconds | |
4kΩ | 1Ω | |||
40kΩ | 10Ω | |||
400kΩ | 100Ω | |||
4MΩ | 1kΩ | |||
40MΩ | 10kΩ | ±(1.0% + 5 digits) | ||
Capacitance | ||||
Range | Resolution | Accuracy | ||
40n/400n/ 4µ/40µ/ 100µF |
0.01n/0.1n/ 1n/10n/ 100nF | ±(2.0% + 10 digits) | ||
Diode Test | Resolution 1mV, Accuracy ±(2.0% rdg ± 5 dgts), Max 5V Open Circuit | |||
Continuity | If continuity exists ≤ 60Ω, built in buzzer will sound | |||
Display | 3¾ digits, 3999 counts |
Digital Storage Oscilloscope | |
Rising Time | Less than 15nS |
Input Impedance | 1MΩ |
Vertical | Number of Channel 1 channel |
Sensitivity 10mV/div - 200V/div (14 divisions) | |
Bandwith DC to 5MHz | |
Sample Rate 25 x 106 samples/s | |
Input Protection 600Vpp | |
Horizontal | Sweep : 125ns ~ 2s/div (23 divisions), Mode : Auto |
Trigger | Auto / Manual with slope rising, falling |
Trigger Adjustable 15% ~ 85% | |
Input Impedance CH A 1MΩ; CH B 50MΩ | |
Maximum Input Voltage CH A 100Vpp; CH B 5Vpp | |
Simultaneously display frequency, period, and rpm | |
Frequency Counter | |
Range | 5Hz ~ 1.3GHz |
Display | 8 digits |
Period Measurement | 5Hz ~ 100MHz |
Internal Gate Time | 0.1s, 1s, 10s |
Input Measurement | CH A : 5Hz ~ 40MHz ; CH B : 40MHz ~ 1.3GHz |
Input Sensitivity | 5Hz ~ 10MHz 100mVrms |
10MHz ~ 40MHz 200mVrms | |
40MHz ~ 80MHz 300mVrms | |
80MHz ~ 1.3GHz 200mVrms | |
Min/Max/Avg | Records min, max, and average; History graph display |
Hold | Captures current reading |
Peak Hold | Records peak max, min; History graph display |
Function Generator | |
Output | Sine, triangle, square wave |
Range | 40Hz ~ 50MHz (6 range) |
Display | 3 digits |
Output Impedance | 600Ω |
Amplitude | 2 ~ 10Vpp |
Duty Cycle | 25% ~ 75% |
Display frequency, period, duty cycle, and amplitude simultaneous in one screen | |
Logic Analyzer | |
Vertical | Input Channel 1 channel |
Input Impedance 1MΩ | |
Protection Level 50Vpp Max | |
Horizontal | Sweep time : 125ns - 2s/div (23 divisions), Mode : Auto |
General Spesifications | |
Power | 6 AA cells (9V Alkaline) or 6 A (7.2V) Ni-Cd battery or 2 rechargeable Ni-Cd battery pack or AC Adapter with internal charger |
Size / Weight | H220 x W107 x D55mm / Approx. 800g |
Standard Accessories | Alligator Clip Set, Test Leads, Holster, AC/DC Power Adaptor with Internal Charger, Ni-Cd Battery Pack, Scope Probe (1:1), BNC/Banana Adaptor, RS232 Interface Cable with Software, Manual, Constant Certificate. |
Optional Accessories | AC Current Adapter, Humidity Adapter, Temperature Adapter, Thermal Printer, Deluxe Carrying Bag, Certificated of Calibration. |
Untuk keterangan lebih lanjut, silahkan download PDF ini :